A backflow preventer is a valve assembly on your water line that only lets water flow one way: into your property, never back out. It keeps things like fertilizer from sprinkler lines or water sitting in a fire system from getting into the public drinking water.

How backflow happens

  • Backsiphonage: pressure in the public main drops, for example during a main break or heavy firefighting draw, and water is pulled backward out of the property like a straw.
  • Backpressure: pressure on the property side rises above supply pressure, from a pump, boiler or elevated tank, and pushes water backward.

How the assembly stops it

Testable assemblies use spring-loaded check valves that only allow flow in one direction. Higher-protection assemblies add a relief valve or an air inlet so that if a check valve leaks, water is discharged or air is let in rather than allowed to flow back.

The main types

  • Reduced pressure principle (RP): two checks plus a relief valve between them. Highest protection, for high hazards.
  • Double check valve (DC): two independent checks. For lower hazards and many fire lines.
  • Pressure vacuum breaker (PVB) and spill-resistant vacuum breaker (SVB): a check and an air inlet, for backsiphonage only, typically irrigation.
  • Detector assemblies (DCDA, RPDA): DC or RP with a metered bypass, used on fire sprinkler services.

Compare them side by side in RP vs. double check vs. PVB.

Why California requires annual testing

Springs weaken, rubber wears and debris lodges in valves. None of that is visible from outside. An annual field test with a calibrated gauge is the only way to confirm the assembly will actually work when it's needed, which is why water suppliers require it. Schedule yours with our backflow testing service.

Related questions

How often does a backflow preventer need to be tested?

Once a year at minimum. A device also needs testing right after it's installed, repaired or moved. Your water district picks the due date and normally mails a reminder ahead of time.

Do houses have backflow devices too?

Many do. Homes commonly have an assembly on the irrigation line, a residential fire sprinkler service, a pool or spa fill line, or a second water source such as a well. If your district sent you a notice, the assembly at that address is on its list.